Signaling Test AT Commands
- AT+FACTPLCP: Send with long or short PLCP (Physical Layer Convergence Procedure) 
Introduction
Important
The default AT firmware supports all the AT commands mentioned on this page. If you don’t need ESP32-C3 to support signaling test commands, you can compile the ESP-AT project by following the steps in Compile ESP-AT Project Locally documentation. In the project configuration during the fifth step, make the following selections:
- Disable - Component config->- AT->- AT signaling test command support
AT+FACTPLCP: Send with Long or Short PLCP
Set Command
Command:
AT+FACTPLCP=<enable>,<tx_with_long>
Response:
OK
Parameters
- <enable>: Enable or disable manual configuration. - 0: Disable manual configuration. The default value for the parameter - <tx_with_long>will be used.
- 1: Enable manual configuration. The type of PLCP that AT sends depends on - <tx_with_long>.
 
- <tx_with_long>: Send with long PLCP or short PLCP. - 0: Send with short PLCP (default). 
- 1: Send with long PLCP.