Signaling Test AT Commands

[中文]

Introduction

Important

The default AT firmware supports all the AT commands mentioned on this page. If you don’t need ESP32-C2 to support signaling test commands, you can compile the ESP-AT project by following the steps in Compile ESP-AT Project Locally documentation. In the project configuration during the fifth step, make the following selections:

  • Disable Component config -> AT -> AT signaling test command support

AT+FACTPLCP: Send with Long or Short PLCP

Set Command

Command:

AT+FACTPLCP=<enable>,<tx_with_long>

Response:

OK

Parameters

  • <enable>: Enable or disable manual configuration.

    • 0: Disable manual configuration. The default value for the parameter <tx_with_long> will be used.

    • 1: Enable manual configuration. The type of PLCP that AT sends depends on <tx_with_long>.

  • <tx_with_long>: Send with long PLCP or short PLCP.

    • 0: Send with short PLCP (default).

    • 1: Send with long PLCP.