HTTP AT Commands¶
AT+HTTPCLIENT: Send HTTP Client Request
AT+HTTPGETSIZE: Get HTTP Resource Size
AT+HTTPCPOST: Post HTTP data of specified length
AT+HTTPCLIENT: Send HTTP Client Request¶
Set Command¶
Command:
AT+HTTPCLIENT=<opt>,<content-type>,<"url">,[<"host">],[<"path">],<transport_type>[,<"data">][,<"http_req_header">][,<"http_req_header">][...]
Response:
+HTTPCLIENT:<size>,<data>
OK
Parameters¶
<opt>: method of HTTP client request.
1: HEAD
2: GET
3: POST
4: PUT
5: DELETE
<content-type>: data type of HTTP client request.
0:
application/x-www-form-urlencoded
1:
application/json
2:
multipart/form-data
3:
text/xml
<”url”>: HTTP URL. The parameter can override the
<host>
and<path>
parameters if they are null.<”host”>: domain name or IP address.
<”path”>: HTTP Path.
<transport_type>: HTTP Client transport type. Default: 1.
1:
HTTP_TRANSPORT_OVER_TCP
2:
HTTP_TRANSPORT_OVER_SSL
<”data”>: If
<opt>
is a POST request, this parameter holds the data you send to the HTTP server. If not, this parameter does not exist, which means there is no need to input a comma to indicate this parameter.<http_req_header>: you can send more than one request header to the server.
Notes¶
If the
url
parameter is not null, HTTP client will use it and ignore thehost
parameter andpath
parameter; If theurl
parameter is omited or null string, HTTP client will usehost
parameter andpath
parameter.In some released firmware, HTTP client commands are not supported (see How to understand the differences of each type of module), but you can enable it by
./build.py menuconfig
>Component config
>AT
>AT http command support
and build the project (see Build Your Own ESP-AT Project).
Example¶
// HEAD Request
AT+HTTPCLIENT=1,0,"http://httpbin.org/get","httpbin.org","/get",1
// GET Request
AT+HTTPCLIENT=2,0,"http://httpbin.org/get","httpbin.org","/get",1
// POST Request
AT+HTTPCLIENT=3,0,"http://httpbin.org/post","httpbin.org","/post",1,"field1=value1&field2=value2"
AT+HTTPGETSIZE: Get HTTP Resource Size¶
Set Command¶
Command:
AT+HTTPGETSIZE=<url>
Response:
+HTTPGETSIZE:<size>
OK
Parameters¶
<url>: HTTP URL.
<size>: HTTP resource size.
Note¶
In some released firmware, HTTP client commands are not supported (see How to understand the differences of each type of module), but you can enable it by
./build.py menuconfig
>Component config
>AT
>AT http command support
and build the project (see Build Your Own ESP-AT Project).
Example¶
AT+HTTPGETSIZE="http://www.baidu.com/img/bdlogo.gif"
AT+HTTPCPOST: Post HTTP data of specified length¶
Set Command¶
Command:
AT+HTTPCPOST=<url>,<length>[,<http_req_header_cnt>][,<http_req_header>..<http_req_header>]
Response:
OK
>
The symbol >
indicates that AT is ready for receiving serial data, and you can enter the data now. When the requirement of message length determined by the parameter <length>
is met, the transmission starts.
If the transmission is successful, AT returns:
SEND OK
Otherwise, it returns:
SEND FAIL
Parameters¶
<url>: HTTP URL.
<length>: HTTP data length to POST. The maximum length is equal to the system allocable heap size.
<http_req_header_cnt>: the number of <http_req_header> parameters.
[<http_req_header>]: you can send more than one request header to the server.
HTTP AT Error Codes¶
HTTP Client:
HTTP Client Error Code
Description
0x7190
Bad Request
0x7191
Unauthorized
0x7192
Payment Required
0x7193
Forbidden
0x7194
Not Found
0x7195
Method Not Allowed
0x7196
Not Acceptable
0x7197
Proxy Authentication Required
0x7198
Request Timeout
0x7199
Conflict
0x719a
Gone
0x719b
Length Required
0x719c
Precondition Failed
0x719d
Request Entity Too Large
0x719e
Request-URI Too Long
0x719f
Unsupported Media Type
0x71a0
Requested Range Not Satisfiable
0x71a1
Expectation Failed
HTTP Server:
HTTP Server Error Code
Description
0x71f4
Internal Server Error
0x71f5
Not Implemented
0x71f6
Bad Gateway
0x71f7
Service Unavailable
0x71f8
Gateway Timeout
0x71f9
HTTP Version Not Supported
HTTP AT:
The error code of command
AT+HTTPCLIENT
will be0x7000+Standard HTTP Error Code
(For more details about Standard HTTP/1.1 Error Code, see RFC 2616).For example, if AT gets the HTTP error 404 when calling command
AT+HTTPCLIENT
, it will respond with error code of0x7194
(hex(0x7000+404)=0x7194
).