ESP MODEM
This component is used to communicate with modems in the command mode (using AT commands), as well as the data mode (over PPPoS protocol). The modem device is modeled with a DCE (Data Communication Equipment) object, which is composed of:
DTE (Data Terminal Equipment), which abstracts the terminal (currently only UART implemented).
PPP Netif representing a network interface communicating with the DTE using PPP protocol.
Module abstracting the specific device model and its commands.
+-----+
| DTE |--+
+-----+ | +-------+
+-->| DCE |
+-------+ | |o--- set_mode(command/data)
| Module|--->| |
+-------+ | |o--- send_commands
+->| |
+------+ | +-------+
| PPP |--+
| netif|------------------> network events
+------+
Modem components
DCE
This is the basic operational unit of the esp_modem component, abstracting a specific module in software, which is basically configured by
the I/O communication media (UART), defined by the DTE configuration
the specific command library supported by the device model, defined with the module type
network interface configuration (PPPoS config in lwip)
After the object is created, the application interaction with the DCE is in
issuing specific commands to the modem
switching between data and command mode
DTE
Is an abstraction of the physical interface connected to the modem. Current implementation supports only UART
PPP netif
Is used to attach the specific network interface to a network communication protocol used by the modem. Currently implementation supports only PPPoS protocol.
Module
Abstraction of the specific modem device. Currently the component supports SIM800, BG96, SIM7600.
Use cases
Users interact with the esp-modem using the DCE’s interface, to basically
Switch between command and data mode to connect to the internet via cellular network.
Send various commands to the device (e.g. send SMS)
The applications typically register handlers for network events to receive notification on the network availability and IP address changes.
Common use cases of the esp-modem are also listed as the examples:
examples/pppos_client
simple client which reads some module properties and switches to the data mode to connect to a public mqtt broker.examples/modem_console
is an example to exercise all possible module commands in a console application.examples/ap_to_pppos
this example focuses on the network connectivity of the esp-modem and provides a WiFi AP that forwards packets (and uses NAT) to and from the PPPoS connection.
Working modes
Modem devices could work in multiple different modes, esp-modem library uses these states to describe them: - Standard modes:
Command mode – This mode is used for sending AT commands
Data or PPP mode – This mode is used for data communication (to create PPPoS tunnel between the device and the library)
- Multiplexing modes:
CMUX mode – This mode creates two virtual channels and uses one for sending AT commands and the other one for data communication.
DUAL mode – This mode uses two physical channels the same way as CMUX. This mode is supported only by certain devices, usually with USB interface.
Manual CMUX modes – These modes are designed for applications to have better control over CMUX mode transitions. It allows setting up the virtual channels, switching between channels, transitioning between data and command modes for each channel separately, and exiting the CMUX.
Switching between common modes
The diagram below depicts allowed transitions between the most common modes
+---------+ +---------+
| COMMAND |<-->| DATA |
+---------+ +---------+
^
|
v
+-------+
| CMUX |
+-------+
Note that it is possible to switch from any mode to the “UNDEF” mode and vice-versa.
Switching between manual modes
The diagram below depicts allowed transitions between manual CMUX modes
+------------------------------------
| |
+----------+ +-------------+ +------------+ +----------+
| |<-->| MANUAL_DATA |<-->| MANUAL_CMD |<-->| COMMAND |
| CMUX | +-------------+ +------------+ | (CMUX |
| MANUAL | | | MANUAL |
| | +-------------+ | EXIT) |
| |<-->| MANUAL_SWAP |<-------------------->| |
+----------+ +-------------+ +----------+
| |
+-----------------------------------------------------+
Note that transitioning between “MANUAL_DATA” and “MANUAL_CMD” switches the secondary terminal (dedicated to PPP session) and could be used for recovering data communication if PPP session gets dropped.
Extensibility
CMUX
Implements virtual terminals which allow users to also issue commands in the data mode; after creating two virtual terminals, designating one of them solely to data mode, and another one solely to command mode.
DTE
Currently, we support only UART (and USB as a preview feature), but modern modules support other communication interfaces, such as USB, SPI.
Other devices
Adding a new device is a must-have requirement for the esp-modem
component. Different modules support different commands, or some
commands might have a different implementation. Adding a new device
means to provide a new implementation as a class derived from
GenericModule
, where we could add new commands or modify the
existing ones.
If you have to support a custom device with C-API, please refer to
the example examples/pppos_client
and enable ESP_MODEM_ADD_CUSTOM_MODULE
.
For advanced use-case, mainly with C++ API and/or usage of esp_modem’s
Factory class, please read <advanced_api>.
Configuration
Modem abstraction is configurable both compile-time and run-time.
Component Kconfig
Compile-time configuration is provided using menuconfig. Please check the description for the CMUX mode configuration options.
Runtime configuration
Is defined using standard configuration structures for DTE
and
DCE
objects separately. Please find documentation of
:cpp:class:
esp_modem_dte_config_t
:cpp:class:
esp_modem_dce_config_t
Known issues
There are certain typical issues you might experience when working with esp_modem. This section elaborates on these problems and offers workarounds.
When using UART terminal, you might find running OTA over https quite unstable, exhibiting frequent UART buffer overflows.
The reason for that is that ESP32’s UART is interrupt driven, so while performing computational extensive tasks with TLS session,
we need to timely interrupt to process incoming data. Here’are few suggestions to mitigate the impact:
* Move UART ISR to IRAM
* Increase internal UART rx buffer size
* Increase UART terminal task priority
* Use UART flow control
If none of the above helps, you can check the test esp_modem/test/target_ota, which performs OTA in two steps – first read the data, then pass the data to mbedTLS. See the test README.md
for more details.
Potential issues when using CMUX mode and these devices:
1) Some modems (e.g. A76xx serries) use 2 bytes CMUX payload, which
might cause buffer overflow when trying to defragment the payload.
It’s recommended to disable ESP_MODEM_CMUX_DEFRAGMENT_PAYLOAD
,
which will fix the issue, but may occasional cause reception of AT command
replies in fragments.
Some devices (such as SIM7000) do not support CMUX mode at all.
3) Device A7670 does no not correctly exit CMUX mode. You can apply this patch to adapt the exit sequence https://github.com/espressif/esp-protocols/commit/28de34571012d36f2e87708955dcd435ee5eab70
diff --git a/components/esp_modem/src/esp_modem_cmux.cpp b/components/esp_modem/src/esp_modem_cmux.cpp
index 0c480f8..4418c3d 100644
--- a/components/esp_modem/src/esp_modem_cmux.cpp
+++ b/components/esp_modem/src/esp_modem_cmux.cpp
@@ -206,6 +206,15 @@ bool CMux::on_header(CMuxFrame &frame)
}
size_t payload_offset = std::min(frame.len, 4 - frame_header_offset);
memcpy(frame_header + frame_header_offset, frame.ptr, payload_offset);
+ if (frame_header[1] == 0xEF) {
+ dlci = 0;
+ type = frame_header[1];
+ payload_len = 0;
+ data_available(&frame.ptr[0], payload_len); // Notify DISC
+ frame.advance(payload_offset);
+ state = cmux_state::FOOTER;
+ return true;
+ }
if ((frame_header[3] & 1) == 0) {
if (frame_header_offset + frame.len <= 4) {
frame_header_offset += frame.len;