ZCL pH measurement

Zigbee Cluster Library (ZCL) pH measurement cluster usage definition for ESP Zigbee SDK.

Header File

Functions

void esp_zb_zcl_ph_measurement_init_server(void)

Macros

ESP_ZB_ZCL_PH_MEASUREMENT_MIN_MEASURED_VALUE_MINIMUM

Minimum value for MinMeasuredValue attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_MIN_MEASURED_VALUE_MAXIMUM

Maximum value for MinMeasuredValue attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_MAX_MEASURED_VALUE_MINIMUM

Minimum value for MaxMeasuredValue attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_MAX_MEASURED_VALUE_MAXIMUM

Maximum value for MaxMeasuredValue attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_TOLERANCE_MINIMUM

Minimum value for Tolerance attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_TOLERANCE_MAXIMUM

Maximum value for Tolerance attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_MEASURED_VALUE_UNKNOWN

Unknown value for MeasuredValue attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_MIN_MEASURED_VALUE_UNKNOWN

Unknown value for MinMeasuredValue attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_MAX_MEASURED_VALUE_UNKNOWN

Unknown value for MaxMeasuredValue attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_MEASURED_VALUE_DEFAULT

Default value for MeasuredValue attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_MIN_MEASURED_VALUE_DEFAULT

Default value for MinMeasuredValue attribute.

ESP_ZB_ZCL_PH_MEASUREMENT_MAX_MEASURED_VALUE_DEFAULT

Default value for MaxMeasuredValue attribute.

ESP_ZB_ZCL_CLUSTER_ID_PH_MEASUREMENT_SERVER_ROLE_INIT
ESP_ZB_ZCL_CLUSTER_ID_PH_MEASUREMENT_CLIENT_ROLE_INIT

Enumerations

enum esp_zb_zcl_ph_measurement_srv_attr_t

pH_Measurement cluster server attribute identifiers

Values:

enumerator ESP_ZB_ZCL_ATTR_PH_MEASUREMENT_MEASURED_VALUE_ID

MeasuredValue Attribute

enumerator ESP_ZB_ZCL_ATTR_PH_MEASUREMENT_MIN_MEASURED_VALUE_ID

MinMeasuredValue Attribute

enumerator ESP_ZB_ZCL_ATTR_PH_MEASUREMENT_MAX_MEASURED_VALUE_ID

MaxMeasuredValue Attribute

enumerator ESP_ZB_ZCL_ATTR_PH_MEASUREMENT_TOLERANCE_ID

Tolerance Attribute