HTTP AT Commands
AT+HTTPCLIENT: Send HTTP Client Request
AT+HTTPGETSIZE: Get HTTP Resource Size
AT+HTTPCGET: Get HTTP Resource
AT+HTTPCPOST: Post HTTP data of specified length
AT+HTTPCPUT: Put HTTP data of specified length
AT+HTTPURLCFG: Set/Get long HTTP URL
AT+HTTPCHEAD: Set/Query HTTP request headers
Introduction
Important
The default AT firmware supports all the AT commands mentioned on this page. If you don’t need ESP32-C3 to support HTTP commands, you can compile the ESP-AT project by following the steps in Compile ESP-AT Project Locally documentation. In the project configuration during the fifth step, make the following selections:
Disable
Component config
->AT
->AT http command support
AT+HTTPCLIENT: Send HTTP Client Request
Set Command
Command:
AT+HTTPCLIENT=<opt>,<content-type>,<"url">,[<"host">],[<"path">],<transport_type>[,<"data">][,<"http_req_header">][,<"http_req_header">][...]
Response:
+HTTPCLIENT:<size>,<data>
OK
Parameters
<opt>: method of HTTP client request.
1: HEAD
2: GET
3: POST
4: PUT
5: DELETE
<content-type>: data type of HTTP client request.
0:
application/x-www-form-urlencoded
1:
application/json
2:
multipart/form-data
3:
text/xml
<”url”>: HTTP URL. The parameter can override the
<host>
and<path>
parameters if they are null.<”host”>: domain name or IP address.
<”path”>: HTTP Path.
<transport_type>: HTTP Client transport type. Default: 1.
1:
HTTP_TRANSPORT_OVER_TCP
2:
HTTP_TRANSPORT_OVER_SSL
<”data”>: If
<opt>
is a POST request, this parameter holds the data you send to the HTTP server. If not, this parameter does not exist, which means there is no need to input a comma to indicate this parameter.<http_req_header>: you can send more than one request header to the server.
Notes
If the length of the entire command containing the URL exceeds 256 bytes, please use the AT+HTTPURLCFG command to preset the URL first, and then set the
<"url">
parameter of this command to""
.If the
url
parameter is not null, HTTP client will use it and ignore thehost
parameter andpath
parameter; If theurl
parameter is omited or null string, HTTP client will usehost
parameter andpath
parameter.In some released firmware, HTTP client commands are not supported (see ESP-AT Firmware Differences), but you can enable it by
./build.py menuconfig
>Component config
>AT
>AT http command support
and build the project (see Compile ESP-AT Project Locally).The command does not support redirection. After getting the status code 301 (permanent redirection) or 302 (temporary redirection) from the server, AT will not automatically redirect to the new URL address. You can use some tools to get the actual URL, and then access it using this command.
If the length of the entire command containing the
<"data">
exceeds 256 bytes, please use the AT+HTTPCPOST command.To set more HTTP request headers, use the AT+HTTPCHEAD command.
Example
// HEAD Request
AT+HTTPCLIENT=1,0,"http://httpbin.org/get","httpbin.org","/get",1
// GET Request
AT+HTTPCLIENT=2,0,"http://httpbin.org/get","httpbin.org","/get",1
// POST Request
AT+HTTPCLIENT=3,0,"http://httpbin.org/post","httpbin.org","/post",1,"field1=value1&field2=value2"
AT+HTTPGETSIZE: Get HTTP Resource Size
Set Command
Command:
AT+HTTPGETSIZE=<"url">[,<tx size>][,<rx size>][,<timeout>]
Response:
+HTTPGETSIZE:<size>
OK
Parameters
<”url”>: HTTP URL. It is a string parameter and should be enclosed with quotes.
<tx size>: HTTP send buffer size. Unit: byte. Default: 2048. Range: [0,10240].
<rx size>: HTTP receive buffer size. Unit: byte. Default: 2048. Range: [0,10240].
<timeout>: Network timeout. Unit: millisecond. Default: 5000. Range: [0,180000].
<size>: HTTP resource size.
Note
If the length of the entire command containing the URL exceeds 256 bytes, please use the AT+HTTPURLCFG command to preset the URL first, and then set the
<"url">
parameter of this command to""
.To set HTTP request headers, use the AT+HTTPCHEAD command to set them.
Example
AT+HTTPGETSIZE="http://www.baidu.com/img/bdlogo.gif"
AT+HTTPCGET: Get HTTP Resource
Set Command
Command:
AT+HTTPCGET=<"url">[,<tx size>][,<rx size>][,<timeout>]
Response:
+HTTPCGET:<size>,<data>
OK
Parameters
<”url”>: HTTP URL. It is a string parameter and should be enclosed with quotes.
<tx size>: HTTP send buffer size. Unit: byte. Default: 2048. Range: [0,10240].
<rx size>: HTTP receive buffer size. Unit: byte. Default: 2048. Range: [0,10240].
<timeout>: Network timeout. Unit: millisecond. Default: 5000. Range: [0,180000].
Note
If the length of the entire command containing the URL exceeds 256 bytes, please use the AT+HTTPURLCFG command to preset the URL first, and then set the
<"url">
parameter of this command to""
.To set HTTP request headers, use the AT+HTTPCHEAD command to set them.
AT+HTTPCPOST: Post HTTP data of specified length
Set Command
Command:
AT+HTTPCPOST=<"url">,<length>[,<http_req_header_cnt>][,<http_req_header>..<http_req_header>]
Response:
OK
>
The symbol >
indicates that AT is ready for receiving serial data, and you can enter the data now. When the requirement of message length determined by the parameter <length>
is met, the transmission starts.
If the transmission is successful, AT returns:
SEND OK
Otherwise, it returns:
SEND FAIL
Parameters
<”url”>: HTTP URL. It is a string parameter and should be enclosed with quotes.
<length>: HTTP data length to POST. The maximum length is equal to the system allocable heap size.
<http_req_header_cnt>: the number of <http_req_header> parameters.
[<http_req_header>]: HTTP request header. You can send more than one request header to the server.
Note
If the length of the entire command containing the URL exceeds 256 bytes, please use the AT+HTTPURLCFG command to preset the URL first, and then set the
<"url">
parameter of this command to""
.the default type of
content-type
isapplication/x-www-form-urlencoded
for this command.To set HTTP request headers, use the AT+HTTPCHEAD command to set them.
AT+HTTPCPUT: Put HTTP data of specified length
Set Command
Command:
AT+HTTPCPUT=<"url">,<length>[,<http_req_header_cnt>][,<http_req_header>..<http_req_header>]
Response:
OK
>
The symbol >
indicates that AT is ready for receiving serial data, and you can enter the data now. When the requirement of message length determined by the parameter <length>
is met, the transmission starts.
If the transmission is successful, AT returns:
SEND OK
Otherwise, it returns:
SEND FAIL
Parameters
<”url”>: HTTP URL. It is a string parameter and should be enclosed with quotes.
<length>: HTTP data length to PUT. The maximum length is equal to the system allocable heap size.
<http_req_header_cnt>: the number of <http_req_header> parameters.
[<http_req_header>]: HTTP request header. You can send more than one request header to the server.
Note
If the length of the entire command containing the URL exceeds 256 bytes, please use the AT+HTTPURLCFG command to preset the URL first, and then set the
<"url">
parameter of this command to""
.To set HTTP request headers, use the AT+HTTPCHEAD command to set them.
AT+HTTPURLCFG: Set/Get long HTTP URL
Query Command
Command:
AT+HTTPURLCFG?
Response:
[+HTTPURLCFG:<url length>,<data>]
OK
Set Command
Command:
AT+HTTPURLCFG=<url length>
Response:
OK
>
This response indicates that AT is ready for receiving serial data. You should enter the URL now, and when the URL length reaches the <url length>
value, the system returns:
SET OK
Parameters
<url length>: HTTP URL length. Unit: byte.
0: clean the HTTP URL configuration.
[8,8192]: set the HTTP URL configuration.
<data>: HTTP URL data.
AT+HTTPCHEAD: Set/Query HTTP Request Headers
Query Command
Command:
AT+HTTPCHEAD?
Response:
+HTTPCHEAD:<index>,<"req_header">
OK
Set Command
Command:
AT+HTTPCHEAD=<req_header_len>
Response:
OK
>
The >
symbol indicates that AT is ready to receive AT command data. At this point, you can enter the HTTP request header (in the format of key: value
). When the data length reaches the value of parameter <req_header_len>
, AT returns:
OK
Parameters
<index>: Index value of HTTP request header.
<”req_header”>: HTTP request header.
<req_header_len>: HTTP request header length. Unit: byte.
0: Clear all set HTTP request headers.
Other values: Set a new HTTP request header.
Note
This command can only set one HTTP request header at a time, but it can be set multiple times to support multiple different HTTP request headers.
The HTTP request headers configured by this command are global. Once set, all HTTP commands will carry these request headers.
If the
key
in the HTTP request header set by this command is the same as that of other HTTP commands, the HTTP request header set by this command will be used.
Example
// Set the request header
AT+HTTPCHEAD=18
// After receiving the ">" symbol, enter the Range request header below to download only the first 256 bytes of the resource
Range: bytes=0-255
// Download HTTP resource
AT+HTTPCGET="https://docs.espressif.com/projects/esp-at/en/latest/esp32c3/index.html"
HTTP AT Error Codes
HTTP Client:
HTTP Client Error Code
Description
0x7000
Failed to Establish Connection
0x7190
Bad Request
0x7191
Unauthorized
0x7192
Payment Required
0x7193
Forbidden
0x7194
Not Found
0x7195
Method Not Allowed
0x7196
Not Acceptable
0x7197
Proxy Authentication Required
0x7198
Request Timeout
0x7199
Conflict
0x719a
Gone
0x719b
Length Required
0x719c
Precondition Failed
0x719d
Request Entity Too Large
0x719e
Request-URI Too Long
0x719f
Unsupported Media Type
0x71a0
Requested Range Not Satisfiable
0x71a1
Expectation Failed
HTTP Server:
HTTP Server Error Code
Description
0x71f4
Internal Server Error
0x71f5
Not Implemented
0x71f6
Bad Gateway
0x71f7
Service Unavailable
0x71f8
Gateway Timeout
0x71f9
HTTP Version Not Supported
HTTP AT:
The error code of command
AT+HTTPCLIENT
will be0x7000+Standard HTTP Error Code
(For more details about Standard HTTP/1.1 Error Code, see RFC 2616).For example, if AT gets the HTTP error 404 when calling command
AT+HTTPCLIENT
, it will respond with error code of0x7194
(hex(0x7000+404)=0x7194
).