Signaling Test AT Commands
AT+FACTPLCP: Send with long or short PLCP (Physical Layer Convergence Procedure)
Introduction
Important
The default AT firmware supports all the AT commands mentioned on this page. If you don’t need ESP32-C6 to support signaling test commands, you can compile the ESP-AT project by following the steps in Compile ESP-AT Project Locally documentation. In the project configuration during the fifth step, make the following selections:
Disable
Component config
->AT
->AT signaling test command support
AT+FACTPLCP: Send with Long or Short PLCP
Parameters
<enable>: Enable or disable manual configuration.
0: Disable manual configuration. The default value for the parameter
<tx_with_long>
will be used.1: Enable manual configuration. The type of PLCP that AT sends depends on
<tx_with_long>
.
<tx_with_long>: Send with long PLCP or short PLCP.
0: Send with short PLCP (default).
1: Send with long PLCP.