Signaling Test AT Commands
AT+FACTPLCP: Send with long or short PLCP (Physical Layer Convergence Procedure)
Introduction
Important
The default AT firmware supports all the AT commands mentioned on this page. If you don’t need ESP32 to support signaling test commands, you can compile the ESP-AT project by following the steps in Compile ESP-AT Project Locally documentation. In the project configuration during the fifth step, make the following selections:
Disable
Component config
->AT
->AT signaling test command support
AT+FACTPLCP: Send with Long or Short PLCP
Set Command
Command:
AT+FACTPLCP=<enable>,<tx_with_long>
Response:
OK
Parameters
<enable>: Enable or disable manual configuration.
0: Disable manual configuration. The default value for the parameter
<tx_with_long>
will be used.1: Enable manual configuration. The type of PLCP that AT sends depends on
<tx_with_long>
.
<tx_with_long>: Send with long PLCP or short PLCP.
0: Send with short PLCP (default).
1: Send with long PLCP.