[RMT] The Idle State Signal Level Might Run into Error in RMT Continuous TX Mode

Affected revisions: v0.0 v0.1 v0.2

Description

In ESP32-C6’s RMT module, if the continuous TX mode is enabled, it is expected that the data transmission stops after the data is sent for RMT_TX_LOOP_NUM_CHn rounds, and after that, the signal level in idle state should be controlled by the “level” field of the end-marker.

However, in real situation, after the data transmission stops, the channel’s idle state signal level is not controlled by the “level” field of the end-marker, but by the level in the data wrapped back, which is indeterminate.

Workarounds

Users are suggested to set RMT_IDLE_OUT_EN_CHn to 1 to only use registers to control the idle level.

This issue has been bypassed since the first ESP-IDF version that supports continuous TX mode (v5.1). In these versions of ESP-IDF, it is configured that the idle level can only be controlled by registers.

Solution

No fix scheduled.