ZigbeeEP
About
The ZigbeeEP class is the base class for all Zigbee endpoints. It provides common functionality for all endpoint types.
Device Information: Every endpoint can be configured with manufacturer and model information that helps identify the device on the network
Binding Management: Binding allows endpoints to establish direct communication links with other devices. This enables automatic command transmission without requiring manual addressing
Power Management: Endpoints can report their power source type and battery status, which helps the network optimize communication patterns
Time Synchronization: Endpoints can synchronize with network time, enabling time-based operations and scheduling
OTA Support: Endpoints can receive over-the-air firmware updates to add new features or fix bugs
Device Discovery: Endpoints can read manufacturer and model information from other devices on the network
ZigbeeEP APIs
Device Information
setManufacturerAndModel
Sets the manufacturer name and model identifier for the device.
bool setManufacturerAndModel(const char *name, const char *model);
name- Manufacturer name (max 32 characters)model- Model identifier (max 32 characters)
This function will return true if set successfully, false otherwise.
setVersion
Sets the application version for the endpoint. The value is stored in the endpoint config and added to the Basic cluster (Application Version attribute). Must be called before Zigbee.begin().
void setVersion(uint8_t version);
version- Application version (0-255)
setHardwareVersion
Sets the hardware version for the endpoint. The value is added to the Basic cluster (Hardware Version attribute). Must be called before Zigbee.begin().
void setHardwareVersion(uint8_t version);
version- Hardware version (0-255)
setDeviceEnabled
Sets the Basic cluster DeviceEnabled attribute (0x0012). When false, the Zigbee stack ignores ZCL commands on this endpoint (the device stays on the network).
Call once before Zigbee.addEndpoint() to add the attribute to the endpoint descriptor (same pattern as setManufacturerAndModel()). After that, setDeviceEnabled() / getDeviceEnabled() work before and after Zigbee.begin(). If the attribute was never added, a call after begin() returns false.
Useful for soft on/off of an endpoint without leaving the network: maintenance mode, temporarily ignoring hub commands while calibrating a sensor, or disabling an unused secondary endpoint on a multi-EP device. A coordinator or other client can also write this attribute remotely once it is exposed.
bool setDeviceEnabled(bool enabled);
enabled-trueto accept ZCL commands (default),falseto ignore ZCL commands on this endpoint
This function will return true if set successfully, false otherwise.
getDeviceEnabled
Returns the current DeviceEnabled value. Useful to check whether the endpoint is accepting commands (for example after a remote write or reboot). If the attribute is not present, returns true (ZCL default).
bool getDeviceEnabled();
setReportingDefaultResponse
Enables or disables Default Response on automatic attribute reports for one attribute.
Call after setReporting() (reporting info must already exist; typically after Zigbee.begin()).
Controls whether automatic reports request a Default Response from the receiver.
Leave enabled (default) when the sketch waits for DefaultRsp to confirm delivery (for example the
sleepy temperature example). Set enabled to false only if reports are fire-and-forget and
you want to avoid the extra response traffic.
bool setReportingDefaultResponse(uint16_t cluster_id, uint16_t attr_id, bool enabled, uint8_t cluster_role = EZB_ZCL_CLUSTER_SERVER);
cluster_id/attr_id- Reportable attribute to configureenabled-trueto request DefaultRsp on reports,falseto disable itcluster_role- Cluster role (default server)
This function will return true if set successfully, false otherwise.
getEndpoint
Gets the endpoint number assigned to this device.
uint8_t getEndpoint();
This function will return the endpoint number (1-254).
Binding Management
bound
Checks if the endpoint has any bound devices.
bool bound();
This function will return true if the endpoint has bound devices, false otherwise.
getBoundDevices
Gets the list of devices bound to this endpoint.
std::list<zb_device_params_t *> getBoundDevices() const;
This function will return list of bound device parameters.
printBoundDevices
Prints information about bound devices to Serial or a custom Print object.
void printBoundDevices(Print &print = Serial);
print- Custom Print object (optional, defaults to Serial)
allowMultipleBinding
Enables or disables multiple device binding for this endpoint.
void allowMultipleBinding(bool bind);
bind-trueto allow multiple bindings,falsefor single binding only
setManualBinding
Enables or disables manual binding mode. Manual binding mode is supposed to be used when using ZHA or Z2M where you bind devices manually.
void setManualBinding(bool bind);
bind-truefor manual binding,falsefor automatic binding (default)
clearBoundDevices
Removes all bound devices from this endpoint.
void clearBoundDevices();
Binding Status
epAllowMultipleBinding
Gets whether multiple device binding is allowed for this endpoint.
bool epAllowMultipleBinding();
This function will return true if multiple bindings are allowed, false otherwise.
epUseManualBinding
Gets whether manual binding mode is enabled for this endpoint.
bool epUseManualBinding();
This function will return true if manual binding is enabled, false otherwise.
Power Management
setPowerSource
Sets the power source type for the endpoint.
bool setPowerSource(uint8_t source, uint8_t percentage = 0xff, uint8_t voltage = 0xff);
source- Power source type (ZB_POWER_SOURCE_MAINS,ZB_POWER_SOURCE_BATTERY, etc.)percentage- Battery percentage (0-100, default: 0xff)voltage- Battery voltage in 100 mV units (default: 0xff)
This function will return true if set successfully, false otherwise.
setBatteryPercentage
Sets the current battery percentage.
bool setBatteryPercentage(uint8_t percentage);
percentage- Battery percentage (0-100)
This function will return true if set successfully, false otherwise.
setBatteryVoltage
Sets the battery voltage.
bool setBatteryVoltage(uint8_t voltage);
voltage- Battery voltage in 100 mV units (e.g., 35 for 3.5 V)
This function will return true if set successfully, false otherwise.
reportBatteryPercentage
Reports the current battery percentage to the network.
bool reportBatteryPercentage();
This function will return true if reported successfully, false otherwise.
Time Synchronization
addTimeCluster
Adds time synchronization cluster to the endpoint. When you want to add a server cluster (have the time and GMT offset) fill the time structure with the current time and GMT offset. For client cluster (get the time and GMT offset) keep the default parameters.
bool addTimeCluster(tm time = {}, int32_t gmt_offset = 0);
time- Current time structure (default: empty)gmt_offset- GMT offset in seconds (default: 0)
This function will return true if added successfully, false otherwise.
setTime
Sets the current time for the endpoint.
bool setTime(tm time);
time- Time structure to set
This function will return true if set successfully, false otherwise.
setTimezone
Sets the timezone offset for the endpoint.
bool setTimezone(int32_t gmt_offset);
gmt_offset- GMT offset in seconds
This function will return true if set successfully, false otherwise.
getTime
Gets the current network time.
struct tm getTime(uint8_t endpoint = 1, int32_t short_addr = 0x0000, const uint8_t *ieee_addr = nullptr);
endpoint- Target endpoint (default: 1)short_addr- Target device short address (default: 0x0000)ieee_addr- Target device IEEE address (default:nullptr)
This function will return network time structure.
getTimezone
Gets the timezone offset.
int32_t getTimezone(uint8_t endpoint = 1, int32_t short_addr = 0x0000, const uint8_t *ieee_addr = nullptr);
endpoint- Target endpoint (default: 1)short_addr- Target device short address (default: 0x0000)ieee_addr- Target device IEEE address (default:nullptr)
This function will return GMT offset in seconds.
OTA Support
The OTA Upgrade client cluster receives a full Zigbee OTA image (not Delta OTA).
Use a dual-OTA partition scheme (for example Zigbee 4MB with spiffs).
Manufacturer code, image type and file version must match the OTA image header and the
coordinator policy (ZHA / Zigbee2MQTT / ESP Zigbee ota_server).
addOTAClient
Adds OTA client to the endpoint for firmware updates. Call before Zigbee.addEndpoint().
bool addOTAClient(uint32_t file_version, uint32_t downloaded_file_ver, uint16_t hw_version, uint16_t manufacturer = 0x1001, uint16_t image_type = 0x1011, uint8_t max_data_size = 48);
file_version- Current firmware version (CurrentFileVersion)downloaded_file_ver-DownloadedFileVersion(0xFFFFFFFF= none stored). Must not equal the image version offered by the OTA server or the stack will skip the download after Query approve.hw_version- Hardware version (passed in Query Next Image when non-zero)manufacturer- Manufacturer code (default: 0x1001)image_type- Image type code (default: 0x1011)max_data_size- Maximum Image Block size (default: 48, the stack default; use 223 with Espressifota_server)
After Zigbee.begin(), requestOTAUpdate() applies hw_version and max_data_size
via the stack APIs.
This function will return true if added successfully, false otherwise.
requestOTAUpdate
Discovers an OTA Upgrade server on the coordinator (Match Descriptor) and sends Query Next Image. Call after the device is connected. Further queries are sent every hour automatically. A coordinator (for example Home Assistant ZHA) can also start an upgrade with Image Notify without this call.
void requestOTAUpdate();
onOTAStateChange / onOTAComplete
Optional callbacks for OTA transfer lifecycle:
void onOTAStateChange(void (*callback)(bool active));
void onOTAComplete(void (*callback)(bool success));
onOTAStateChange-truewhen download/apply becomes active,falsewhen inactiveonOTAComplete-trueon successful FINISH (before reboot),falseon abort/failure
Creating a Zigbee OTA image (Export)
With Tools → Zigbee Mode enabled and OTA macros / addOTAClient() in the
sketch, Sketch → Export compiled Binary runs tools/zb_ota_image.py and
writes MMMM-TTTT-VVVVVVVV-ota-file.zigbee beside the .bin (build folder
and sketch/build/<fqbn>/).
Sketch #define literals the tool reads:
OTA_UPGRADE_MANUFACTURER(default0x1001if omitted but OTA is detected)OTA_UPGRADE_IMAGE_TYPE(default0x1011)OTA_UPGRADE_FILE_VERSIONorOTA_UPGRADE_RUNNING_FILE_VERSION(required; must be greater than the version running on the device for ZHA to offer it)Optional:
OTA_UPGRADE_MIN_HW_VERSION+OTA_UPGRADE_MAX_HW_VERSION(only if you need hardware filtering; omit for ZHA local-file testing), andOTA_UPGRADE_HEADER_STRING
The hook soft-skips (does not fail Export) when Zigbee Mode is Disabled, the sketch has no OTA intent, or required macros are missing.
Manual alternative: Espressif’s image_builder_tool (see Generate and apply OTA upgrade image).
OTA with Home Assistant ZHA
Until you place any matching .zigbee file in the Home Assistant OTA folder
(zigpy_ota), ZHA shows the device firmware as Unknown — it has nothing
to compare against. Upload an image with the same version as the firmware
already on the device to see Up-to-date, or a newer version when you want
an Update available.
USB-flash a build that is already joined to ZHA (note the running
OTA_UPGRADE_RUNNING_FILE_VERSIONon Serial).Bump
OTA_UPGRADE_RUNNING_FILE_VERSIONto a higher value (do not USB-flash that build), keep Zigbee Mode enabled, and use Sketch → Export compiled Binary to produce the.zigbeefile (or wrap the.binwithimage_builder_tool). ZHA only offers images newer than the device’s current file version.On Home Assistant, install the Samba share add-on (or another way to reach the
configfolder). Createconfig/zigpy_ota/and copy the.zigbeefile there.Add Zigpy OTA config to
configuration.yaml. Theadvancedprovider requires the exactwarningtext below (do not paraphrase — zigpy rejects any other string):zha: zigpy_config: ota: extra_providers: - type: advanced path: /config/zigpy_ota warning: >- I understand I can *destroy* my devices by enabling OTA updates from files. Some OTA updates can be mistakenly applied to the wrong device, breaking it. I am consciously using this at my own risk.
After copying or replacing the
.zigbeefile, open Settings → Devices & services → Zigbee Home Automation, click the ⋮ (three dots) on the ZHA integration card, and choose Reload so the OTA provider picks up the new file (a full Home Assistant restart also works).Join the Arduino end device if needed, open the device page and use Update to start the firmware upgrade. Wait until the device reboots on the new image.
Device Discovery
readManufacturer
Reads the manufacturer name from a remote device.
char *readManufacturer(uint8_t endpoint, uint16_t short_addr, const uint8_t *ieee_addr);
endpoint- Target endpoint numbershort_addr- Target device short addressieee_addr- Target device IEEE address
This function will return pointer to manufacturer string, or NULL if read failed.
readModel
Reads the model identifier from a remote device.
char *readModel(uint8_t endpoint, uint16_t short_addr, const uint8_t *ieee_addr);
endpoint- Target endpoint numbershort_addr- Target device short addressieee_addr- Target device IEEE address
This function will return pointer to model string, or NULL if read failed.
Event Handling
onIdentify
Sets a callback function for identify events.
void onIdentify(void (*callback)(uint16_t));
callback- Function to call when identify event occurstime- Identify time in seconds
identifyQuery
Sends an Identify Query command. Devices that are currently identifying reply with an Identify Query Response
(see onIdentifyQueryResponse). Useful for finding & binding style discovery: broadcast a query and collect
responses from devices the user has put into identify mode (for example via the hub or a button).
bool identifyQuery(uint16_t short_addr = 0xFFFF, uint8_t dst_endpoint = EZB_AF_ENDPOINT_BROADCAST_ID);
short_addr- Destination short address (default0xFFFF= broadcast)dst_endpoint- Destination endpoint (default broadcast endpoint)
This function will return true if the command was sent, false otherwise.
onIdentifyQueryResponse
Sets a callback for Identify Query Response messages received on this endpoint.
void onIdentifyQueryResponse(void (*callback)(uint16_t timeout, uint8_t src_endpoint, ezb_address_t src_address));
callback- Function to call for each responsetimeout- Remaining identify time in seconds on the remote devicesrc_endpoint- Endpoint of the identifying devicesrc_address- Address of the identifying device
onDefaultResponse
Sets a callback for default response messages for this endpoint.
void onDefaultResponse(void (*callback)(zb_cmd_type_t resp_to_cmd, ezb_zcl_status_t status));
callback- Function pointer to the callback function
This callback will be called when a default response is received for this specific endpoint.
Supported Endpoints
The Zigbee library provides specialized endpoint classes for different device types. Each endpoint type includes specific clusters and functionality relevant to that device category.
- ZigbeeAnalog
- ZigbeeBinary
- ZigbeeCarbonDioxideSensor
- ZigbeeColorDimmableLight
- ZigbeeColorDimmerSwitch
- ZigbeeContactSwitch
- ZigbeeDimmableLight
- ZigbeeDoorLock
- ZigbeeDoorWindowHandle
- ZigbeeElectricalMeasurement
- ZigbeeFanControl
- ZigbeeFlowSensor
- ZigbeeGateway
- ZigbeeIlluminanceSensor
- ZigbeeLight
- ZigbeeMultistate
- ZigbeeOccupancySensor
- ZigbeePM25Sensor
- ZigbeePowerOutlet
- ZigbeePressureSensor
- ZigbeeRangeExtender
- ZigbeeSwitch
- ZigbeeTempSensor
- ZigbeeThermostat
- ZigbeeVibrationSensor
- ZigbeeWindSpeedSensor
- ZigbeeWindowCovering